Dongguan Eidoll Elect. Co., Ltd. sales the Sensata YS10 series, the specifications as bellow:
Introduction
•
High current capacity (125Vac/16A) to cut off power circuit
•
Keep small size as conventional protector MA10, and thermal sensitivity
•
Reliable long life
Features
YS10 was
developed to protect people and property from accidents occurring on products
such as Hair Dryer/Fan heater. It is an automatic resettable, incorporated
thermal cut-out (Type 2C).
The YS10
pursued to enable to be used for higher wattage products, therefore highest
current can be loaded through YS10, and directly cut off power line. But the
distance of mounting holes is kept at same size as conventional protector MA10.
SPECIFICATIONS
Contact Capacity
|
12(3)A 250Vac 16(3)A 125Vac
|
Temperature Range
|
¡À 5K
|
Tolerance on Open Temperature
|
60 to 150¡ãC
|
Max. Temp. of Switch Head
|
150¡ãC
|
Operating Time
|
Continuous
|
Pollution Situation
|
Norma
|
Extent of Sensing Element
|
Whole Contro
|
Performance
Ultimate
Trip Current Curve
DIMENSIONS
Dimensions
in mm Width 5.6 x Length 31.5 x Height 3.5mm Distance between each hole :
26.5mm Hole Diameter : 2.7mm
Construction
YS10 is
constructed with only few parts as a simple and open design (IP00) and based on
the well known thermostat technology of Texas Instruments.
1.Upper
Terminal carries current to 2.Lower Terminal which is insert molded in 3.Lower
Block, via 4.Movable Arm, 5.Movable Contact and 6.Stationary Contact. All parts
are riveted to hold with 8.Eyelet. Refer drawing 7.Bimetal Disc is placing
under 4.Movable Arm to push it up to open Contact, when 7.Bimetal Disc sensed
high ambient temperature around YS10. Heat generated by 4.Movable Arm is
designed properly on a combination with operation temperature and Trip current.
Therefore, user could select best choice of MUST HOLD current for their
product. The YS10 is mounted by various means in conjunction with (holes in)
the terminals, such that adequate creepage and clearance distances are
maintained between live parts and accessible metal parts.
The electrical
connections are for internal wiring only and are achieved by e.g. riveting,
soldering or spot welding.
Terminal
Identification
ORDERING
OPTIONS
Example :
YS10 01B-S
120¡ãC
operation temperature, BeCu Movable Arm, Standard Terminals and 30¡ãC
differential. (90¡ãC reset)
|